Maccor - Product Overview

Maccor, Inc. designs and manufactures fully programmable automated multiple station secondary (rechargeable) and primary cell test systems, programmable electronics to sink and source current, Frequency Response Analysers, and cell formation equipment to name a few.
Systems can be easily customized with voltages up to 480VDC and currents ranging from 300nA to 2000 Amps. If you do not see something that meets your needs, contact us with your requirements. There is a good chance we can build it.

Since 1986, the source for battery and cell test equipment. With equipment in operation in 40 countries around the world, Maccor in our market has delivered more test positions than all competitors combined!

Primary Cell Testers
Two main products have been specifically designed to reach this market segment, the Series 3600 and the Series 3650. These products combine function and density to provide an affordable solution to meet the increasing demands of primary tests.

Formation Equipment

Maccor's formation equipment consists of 256 cell position modules. Each formation system can have from one to eight modules yielding 2,048 position cell formation systems.

Electrochemical
The Frequency Response Analyzer performs frequency scans from sub milliHertz frequencies to 30kHz with extremely accurate readings at low impedances. The EDA 0356 with its multiplexer make it the perfect addition to an existing Maccor test system for the serious user, or use it as a stand-alone Frequency Response Analyzer.

Software
Maccor's 32-bit software is both powerful and easy to use. Meeting all your testing needs is simple. In the event Maccor's standard software does not meet your needs, custom features and options may be purchased.

Options
System options may be purchased with the test system or in most cases added in the field by a Maccor field service engineer. System options include: Reference Voltage Inputs, Thermocouple Inputs, Thermistor Inputs, Pressure Sensor Inputs, LED Status Indicators, SMBus Reading Capability, Digital Inputs, Digital Outputs, External Charge Controllers, External Discharge Controllers, Telecom Pulsing, and Sub-millisecond Pulsing.

Accessories
A wide range of accessories are available to enhance the use of your Maccor system, from a UPS that ensures no data is lost during a power outage to a selection of cell holders and cables offering you a range of user interfaces

Service & Calibration
As the Maccor authorized agents for Europe CellCare Technologies provide a full service and calibration service as well as technical support on your Maccor system.

Model Range

EDA 0305 Frequency Response Analyzer
The EDA 0305 Frequency Response Analyzer is the right system at the right price for measuring low impedances devices. In no time at all, the EDA 0305 Frequency Response Analyzer will become one of the most valuable research tools in your laboratory. Designed primarily for use in AC impedance evaluation of batteries, super capacitors, or any where the accuracy of low impedance values is essential >More.

series 2300 - This 8 channel unit is intended for bench top mounting, typically for use in small research laboratories and other applications requiring a small number of test channels at relatively low current and voltage. The Model 2300 can be used for 3 electrode measurements, with or without the thermocouple option >More.

series 3600 - The multifunction SERIES 3600 primary cell test system has been engineered to meet the growing demands of existing and upcoming ANSI and IEC test standards. Each test position: Operates independently of the other positions; Can be user programmed to run a wide range of multi step tests, including pulse tests; Can be user programmed to operate in steps of fixed current, fixed power, fixed voltage, fixed resistance; Has a dynamic range of over 25,000 to 1 to meet ANSI and IEC standards of current, power and resistance >More.

series 3650 - The multifunction SERIES 3650 primary cell test system has been engineered to meet the growing demands of existing and upcoming ANSI and IEC tests. Each test position: Operates independently of the other positions; Can be user programmed to run a wide range of multi step tests, including pulse tests; Can be user programmed to operate in steps of fixed current, fixed power, fixed voltage, fixed resistance; Has a dynamic range to ANSI and IEC standards of current / power / resistance of over 25,000 to 1.>More.

series 4000 - A family of automatic battery test systems based upon the same hardware components and software operating system. Within this series Maccor offers different system configurations to provide the customer with a choice of size, features and cost. All Series 4000 systems are multi-channel, computerised, and capable of fully automatic testing. Using the Maccor Windows TM based software, an almost unlimited variety of test programs can be performed, to provide extensive information on battery performance. The Series 4000 test systems are an essential tool for research, development and quality control for all types of batteries >More.

series 4300 - This unit can be configured from 1 - 8 channelis and is intended for bench top mounting, typically for use in small research laboratories and other applications requiring a small number of test channels at currents up to 120A and voltages up to 10V. The Model 4300 can be used for 3 electrode measurements, with or without the thermocouple option >More.

series 4304 - This 4 channel unit is intended for bench top mounting, typically for use in small research laboratories and other applications requiring a small number of test channels at relatively low current and voltage.>More.

series 4600/4650 - The multifunction SERIES 4600/4650 secondary cell test systems have been engineered to provide high capabilities for large scale single cell testing. Each test position: Operates independently of the other positions; Can be user programmed to run a wide range of multi step tests; Can be user programmed to operate in steps of constant current, constant power, constant voltage, or constant resistance. >More.

series 5300 - These systems are designed for use in the formation / production testing process of Lithium / Ni-Cd / Ni-MH cells. Each system is specifically built to meet the customer's needs in terms of cell production rate, type, size and configuration of cell, and the level of automation.
This system operates under a dedicated Microsoft Windows TM based software program specifically written by Maccor for these systems. Features include pre-programmed formation and test profiles, automatic calibration, cell fault detection, the ability to sort cells and simple on-screen displays.
The Series 5000 combines the requirements of both formation and production testing into one flexible and easy operating system >More.

series 8000 - The Series 8000 is a range of fully automated, computerized battery test systems that provide the highest level of specifications and features available in a Maccor test system. The Series 8000 provides exceptional accuracy (99.95% of Full Scale), resolution (16-bit, 1 part in 65,536) and speed (1 mS data aquisition, available) for testing Hybrid Electric Vehicle (HEV) batteries, Super Capacitor, and other high power energy storage devices.>More.

     