The multifunction
SERIES 4600/4650 secondary cell test systems have
been engineered to provide high capabilities for
large scale single cell testing. Each test position:
Operates independently of the other positions;
Can be user programmed to run a wide range of
multi step tests; Can be user programmed to operate
in steps of constant current, constant power,
constant voltage, or constant resistance.
The Series 4600/4650 is supplied as a complete
turnkey system with PC computer and software.
Each system is available from a desktop model
to large test and quality control models with
thousands of test positions. Desktop models are
usually available from stock.
Powered by Maccor's standard battery testing software
and utilizing similar technology as found in Maccor's
high precision Series 4000 laboratory test systems,
the Series 4600/4650's are ideal for today's testing
standards. During the test, data is recorded at
operator specified intervals. At any time during
the test, data can be viewed or plotted. The software
can be configured to automatically add key test
data to Maccor's
MIMS database. Additionally, custom data handling
interfaces or user interfaces can be purchased.
The Model 4600 has a Phoenix connector interface
with horizontal cell configuration providing a
dense and compact configuration. Each cabinet
(standard 19" rack) can have up to 192 test
positions. The Model 4600 is also available in
a desktop cabinet with 32-test positions.
The Model 4650 has a Powerpole® interface
with vertical cell configuration. The 4650 has
a slightly larger footprint than the 4600, each
cabinet can be configured with as many as 256
test positions.
For production and quality control systems, test
positions can be accessed remotely with a PC over
a wireless network interface allowing the operator
to view, start, and stop tests directly at the
cell interface.
|
|
|
|
- Number of Test Channels:
32 to 256 per cabinet
- Voltage Measurement Range:
0 V to +5 V
- Voltage Accuracy:
±5 mV
- Minimum Discharge Voltage:
0.2 volts or 0.35 × Current, whichever is greater
- Voltage Resolution:
16 bit
- Current Range
2500 mA Full Scale
- Current Accuracy:
±2.5mA
- Maximum Charge Current:
60 Amps per 32 Cell Module
- Current Resolution:
16 bit
- Time Resolution:
50 mS
- Minimum Step Time:
500 mS
- Data Recording Rate:
200 data points per second per system standard
- Operating Modes:
Constant Current, Constant Voltage, Constant Power, Constant
Resistance
- Number of Steps per Test:
127 standard plus subroutines
If you require further
information about this product or service please contact us
here
|