The
Series 4000 is a range of fully automated, computerized
battery test systems that provide the highest level
of specifications and features available in a Maccor
test system. From the base system that provides
exceptional accuracy and high speed testing capability
with an advanced level of integrity, features can
be added to allow the Series 4000 system to perform
virtually any type of cell or battery test, with
any battery chemistry.
The Series 4000 systems are available in sizes from
8 to 256 test channels. Systems are custom manufactured
to meet your specific needs. They can be configured
with a wide range of voltage and current ranges,
and can be fitted with additional hardware to provide
a number of optional features and capabilities.
Supplied as a complete turnkey system, the Series
4000 consists of a test cabinet, PC computer and
test software,
with options of a UPS and Printer. The test cabinet
and PC computer are connected via a high-speed 10
Base T communications network. As soon as AC power
is connected to the test system, it is ready for
immediate use.
To provide maximum flexibility and speed of operation,
single board computer controllers within the test
cabinet provide control of the tests and collect
the initial data. Each controller supports from
one to eight test channels, dependent on the application.
In addition, the test cabinet contains the individually
controlled electronic loads, and power supplies
for charging purposes.
Each test channel is operated independently. This
allows different tests to be performed on different
test channels simultaneously, with tests being started
independently, or in a block. Once started, tests
operate completely automatically until the appropriate
test end condition is reached.
- Number of Test Channels:
8 to 256 per system
- Voltage Ranges:
available up to 480 V maximum
- Voltage Accuracy:
0.02% of full scale voltage
- Voltage Resolution:
16 bit
- Current Ranges:
Single Current Range 1 mA to 2000 A; Four Current
Ranges: 150 uA, 5 mA, 150 mA, 5 A
- Current Accuracy:
0.02% of full scale current
- Current Resolution:
16 bit
- Time Resolution:
10 mS standard, with 5 mS and 1 mS as an option
- Minimum Pulse width:
100 uS
- Rise Time:
500 uS standard in constant current modes, 100uS
or 20 uS optional
- Switch Time:
Full charge to full discharge 400 mS standard
<500 uS optional
- Data Recording Rate:
200 data points per second per system standard
- Data Recording Interval:
Time (minimum 10 mS standard, 5 mS and 1 mS
available), V, I, Ah, Wh, T, P
- Operating Modes:
Constant Current, Constant Voltage, Constant
Power, Constant Resistance, Ramp Voltage
- Number of Steps per Test:
127 standard plus subroutines
- Step End Conditions:
Voltage, Current, Time, -dV, dV/dT, dV/dt, Ah,
Wh, HCAh, HC Wh, LHC Ah, LHC Wh, Auxiliary Voltage,
Reference Electrode Voltage, Temperature, dT/dt,
dT/dt, pH, Pressure
If you
require further information about this product
or service please contact us here
|